cdaq 9178. I find a cDAQ-9178 chassis in our lab without the power supply. cdaq 9178

 
 I find a cDAQ-9178 chassis in our lab without the power supplycdaq 9178  The chassis provides the plug-and-play simplicity of USB to sensor and electrical measurements

Member. Each channel has a digital I/O pin to which you can connect a digital input or output device. Locate the cDAQ in NI MAX, and note its name. The output power and fuel consumption are measured. When I go to MAX (Measurement & Automation Explorer) and go to the "Devices and Interfaces", and I press F5 (Refresh), it can not detect NI 9178. It also controls the timing, synchronisation, and data transfer between C Series I/O modules and an external host. Using the DAQmx driver, signals can be exported from a master task by using the NI-DAQmx Export Signal Property Node. Capture a Unique Event in Incoming Data. Options. NI cDAQ-9178. The T60 UV-visible spectrophotometer and the NI cDAQ – 9178 were used to measure the optical transmittance and the sheet resistance of the Cu NW electrode, respectively. In principle this should thus go from 0 to 1 Volt in 1 second. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. Controlla anche la temporizzazione, la sincronizzazione e il trasferimento dati tra moduli I/O C Series e un host esterno. ハードウェアによってサポートされていないため、指定された経路を処理できません。. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. I am trying to make an example to test how to measure voltage and current with the above cDAQ device. This page is part of the CompactDAQ System. National Instrument NI cDAQ-9178 Manual Start DAQExpress: Step 1: Turn on the system by connecting to an outlet using output number 4 above. LoadDevice ("dev1"); Member. The frame of the experimental setup was constructed of 10 mm thick Plexiglas sheet. Figure 12: NI cDAQ-9178 with two BNC ports can be used to import or export timing and trigger signals. This limits the system to two tasks with different oversample clock timebases. I have a basic circuit with a switch that is activated when the output is 20 mA, and off when the current is 0 mA. Also, 6 test sections. The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. Bookmark. 0 scans/sec 32 channels ('ai0' - 'ai31') 'Voltage' measurement type This module is in slot 1 of the 'cDAQ-9178' chassis with. cDAQ-9178製品 の 規格 認証 - NI ホームページに戻る Re: Want to reset CDAQ-9178 chassis via my C# program, Ryan_K. I have a cDAQ-9178 with NI 9221 connected taking 3 pressure readings. 1AS protocol. Watch this video or follow the instructions provided. 3. com | NI 9923 User Guide and Specifications Connecting the Signals To wire the NI 9923, complete the following steps while referring to Figure 2. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. 1 mm (0. 低周波数信号の場合、使用するカウンタまたは内部タイムベースは1つで十分です。. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. 5V Everything is wired correctly. The burner, burn structure, propane source, and measure-ment setup were all identical to the setup de-scribedin(Abbasiet al. 16-Channel, 75 S/s Aggregate, ±78 mV C Series Temperature Input Module. Note Some C Series I/O modules have additional power requirements. Controlla anche la temporizzazione, la sincronizzazione e il trasferimento dati tra. b) Connect the ring lug to the ground terminal on the side of the NI cDAQ-9178 using the ground screw. The device is in an NI cDAQ-9178 chassis in slot 3 with ID cDAQ1Mod3. 0 Chassis NI cDAQ-9171/9174/9178 User Manual July 2016 372838E-01 NI cDAQ TM-9171/9174/9178 User Manual NI CompactDAQ USB 2. 7 with no change, that is cDAQ-9178 not recognized in MAX or by Windows Device Manager. 0 communication. 06-17-2016 06:17 PM. For more information about C Series I/O module power requirements, refer to the documentation for each C Series I/O module. Reconnect Device - Unplug & replug device, switch USB port. This solution might also apply to other similar products or applications. Figure 8. representative photo click to zoom Weight: 2. The example uses two National Instruments CompactDAQ analog input modules (9201 and 9211) that have different acquisition rate limits. In terms of specifications, the two cDAQ chassis should have almost exactly the same specs (at least in all the ways that would affect that connection) -- the only main difference is the number of modules, as you mentioned. The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. The cDAQ-9171 (Part Number: 781425-01) is a bus-fueled CompactDAQ Chassis, intended for small and convenient sensor estimation frameworks. 8‑Slot, USB CompactDAQ Chassis. This page documents all the applicable standards and certifications for the cDAQ-9178 and provides downloadable certifications. The latest version of DAQmx now is the 9. Ltd, Beijing) and iso -octane (99. 그림 5는 NI 9203과 함께 NI cDAQ-9178 섀시를 사용한 참조 단일 종단(RSE) 전류 측정의 연결 다이어그램과 모듈의 핀아웃을 보여줍니다. National Instrument NI cDAQ-9178 Manual Start DAQExpress: Step 1: Turn on the system by connecting to an outlet using output number 4 above. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. NI Device Driversは、NI-DAQmx、NI-VISA、NI-SCOPE、NI-SWITCHをはじめ、ほとんどのNI計測器ドライバが含まれているバンドル製品です。. Okay, thank you for the answers. A programmable power source (Koard KA3005P) powers the heater. 0 has the following requirements: 1 GHz or faster 32-bit (x86) or 64-bit (x64) processor. 5. 4. Using LabVIEW (National Instruments, USA) acoustic software, the commencing and ceasing of recordings were. Whether you are creating a new configuration, replacing or expanding your current CompactDAQ System, or verifying that existing parts can be used in a different configuration, this guide can help. Attach the other end of the wire to the system safety ground. NI cDAQ TM-9171/9174/9178 User Manual NI CompactDAQ USB 2. Combine the cDAQ-9178 with up to eight NI C Series I/O modules for a custom analog input, analog output, digital I/O, and counter/timer measurement system. 第一步要先安装好labview和DAQmx驱动,要注意他们之间版本的兼容性,发布时间相差太大的话就不兼容了。. The chassis provides the plug‑and‑play simplicity of USB to. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. Rack-Mounting Enclosure - Is an accessory you can use to mount a CompactDAQ controller and chassis, or an. The National Instruments cDAQ-9178 8-Slot, USB CompactDAQ Chassis is designed for small, portable sensor measurement systems. 04-26-2017 01:11 AM. It includes a high-resolution mode with 50/60 Hz rejection to remove low frequency noise. Scenario 2 - I have recently procured new cDAQ - 9178 for new ATE but it is not detecting PXIe but the same works in Host System. Buy 781156-01 - Ni - Chassis, cDAQ-9178, CompactDAQ Systems, 8 Slots, USB 2. to verify your subscription or service agreement is valid. Software Support for CompactRIO, CompactDAQ, Single-Board RIO, R Series, and EtherCAT. 我开发了一个应用程序,实现的是使用NI DAQ采集卡采集数据。我发布了一个独立运行的可执行文件,同时也在我的开发计算机上发布了相应的安装程序。当我在第二台计算机上使用安装程序安装应用程序时,它能够按预期正常工作。但是,当我进入NI Measurement and Automation Explorer(NI MAX)并点击设备后. Using this trigger source, the cDAQ does not register the trigger at all. 08-28-2022 06:49 PM. You can request repair, RMA, schedule calibration, or get technical support. You can use the digital module to access the counters on the cDAQ chassis, and generate a pulsetrain using those counters. ) 20. 本文主要介绍NI公司图形化编程语言-虚拟仪器LabVIEW软件如何调用NI公司的‍基于C语言的开发环境-LabWindows CVI开发语言生产的(Dynamic Link Library,缩写为 DLL),实现不同开发环境之间LabVIEW和C语言的接口互连,提高不同开发环境之间. Click Create Task. Re: Want to reset CDAQ-9178 chassis via my C# program, Ryan_K. Member. Make sure the NI cDAQ-9178 power source is not connected. ) 88. See all Driver Software Downloads. Create a DataAcquisition object, and add an analog input channel with IEPE measurement type. czech@ni. 1 shows the schematic of the RCM experimental setup. Data Acquisition Toolbox Support Package for National Instruments ® NI-DAQmx Devices provides support for CompactDAQ, FieldDAQ™, X-Series, M-Series, E-Series, USB, myDAQ, ELVIS II, and many other types of data acquisition hardware from National Instruments through MATLAB and Data Acquisition Toolbox. NIコミュニティのメンバーとのネットワーク作りや情報共有が可能です。. Ensure that power is disconnected from the CompactDAQ chassis. 2D Dimensional Drawings. Figure 5 shows the connection diagram for Reference Single-Ended (RSE) current measurements using an NI cDAQ-9178 chassis with an NI 9203 as well as the pin-outs for the module. 50 1 $ 797. To do this hold down the Reset button for more than 5 seconds and then release it. (this is NI cDAQ 9178 plugged via USB on a Windows 10 computer, and with the NI 9264 output module wired to a multimeter so that I can check the output changing) # Continuous write single channel. CTR 0 GATE, pin 2 to first frequency signal. NI-DAQ™mxをダウンロードして、サポート情報をご確認ください。. El procedimiento es similar cuando se usa un instrumento o dispositivo de medición diferente. CDAQ-9178, COMPACTDAQ CHASSIS (8. Briefly, the RCM has a diameter of 50. MXI-Express DAQ Chassis on a standard 19-inch rack. I have cDAQ 9178 device and its no detecting on my computer. d = daq ( "ni" ); ch = addinput (d, "cDAQ1Mod3" ,0, "IEPE" ); Change the channel ExcitationCurrent property value to 0. The fluorescence signals in addition to TTL signals from behavioral settings were digitized by a data acquisition module (cDAQ-9178, National Instruments), and simultaneously recorded using a. You will then to need restart your system. The chassis provides the plug. The chassis provides the plug-and-play simplicity of USB to sensor and electrical measurements. Desktop Mounting - For any CompactDAQ chassis to facilitate the wiring and removal of I/O modules during development. 999%, Praxair Gas Co. The non-Iinear loads are evaluated by measurements as two-port networks and various powers associated with the load are determined according to the. 0 Chassis NI cDAQ-9171/9174/9178 User Manual July 2016 372838E-01The cDAQ‑9171 is a bus‑powered, CompactDAQ USB chassis designed for small, portable sensor measurement systems. It seems adding the below code helped. The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. The drivers for this device are not installed. Create Synchronized Signals. The cDAQ-9178 is a compact and versatile USB chassis that can host up to eight C Series I/O modules for various sensor and electrical measurements. Starten Sie den Computer neu, wenn Sie dazu aufgefordert werden. During Debugging i tried connecting new cDAQ-9178 and tried connecting old PXIe but still its not. The cDAQ‑9179 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. If you recently installed to a newer version of LabVIEW, try repairing the DAQmx driver. 价格不含税。. 8 | NI cDAQ-9178 Specifications | ni. DAQmx is now updated to 9. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. In experiments, the upstream stagnation temperature ranged from 34. Scenario 1 - I have one cDAQ - 9178 and it works perfectly fine in one of our ATE (Automated Test Equipment). This page provides dimensional drawings for the cDAQ-9178. 修理、RMA、キャリブレーション予定. 所需设备: ni compactdaq机箱; ni 9401八通道,5 v / ttl高速双向数字i / o模块; 24脉冲/转旋转正交编码器 For this section, consider an example using the NI cDAQ-9178 chassis and the NI 9401 C Series digital I/O module. c. digikey. (b) Heating test equipment, on the front the heater, on the back from left to right, DC power supply, data logger,. The RDE was controlled using a RDE710 Rotating Electrode setup from Gamry Instruments. 0 Controller that your device is plugged into, right click it, and select Properties. 2) to the PC via a data acquisition chassis (NI No. 3. . The DAQ is outputting a counter signal for controlling a motor (or a similar device). 02-17-2017 09:58 AM - edited ‎02-17-2017 10:02 AM. NI cDAQ-9178 / Voltage input module: NI-9205 / Digital input/output module: NI-9401 / Digital output module: NI-9474 / Temperature input module: NI-9213 / The experimental data (data acquisition sampling rate is 1 kHz) is obtained by NI's Compact-DAQ module and LabVIEW tool. Select NI-9426 and NI-9475 modules need to be updated to support cDAQ. 入力信号の立ち上がりエッジが内部タイムベースのティック数のトリガとなり、カウント. The cDAQ-9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. Power Supply Mounting Kit 199432-01. 08-19-2013 05:08 AM. cDAQ-9178 寸法図 National Instruments cDAQ-9178 8-Slot, USB CompactDAQ Chassis. There is also a Ni-9401 which I can use. The data were recorded at 100 kHz using a National Instruments data acquisition system (cDAQ-9178 chassis coupled with analog input model cDAQ. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. 1TDP5: Before the charging cycle, the air-blower was connected to the top side of the packed-bed system. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. com. The 9211 module is used for temperature measurements and acquires at a slower rate (10 Hz) than the 9201. The Chassis gives the plug and play simplicity of USB to. a. Options. cDAQ-9178 chassis, NI 1913 thermocouple module input and an NI 9219 universal analog input module for measuring voltage and current. 開発用コンピュータにLabVIEWがインストールされ、アクティブ化されたので、次にハードウェアを接続します。. 1) using windows 10 operating system 64 bit. Connect the NI cDAQ-9178 chassis to your host computer. The cutting and thrust forces were measured by a piezoelectric multi-component dynamometer 9257B (Kistler Instrument Co. cDAQ-9178 USB-6212 Driver. Member. ans = ni: National Instruments NI 9205 (Device ID: 'cDAQ1Mod1') Analog input supports: 4 ranges supported Rates from 0. when connected to the USB 2 port, a beep is generated in Windows, along with a notification that the USB Device Not Recognized. EN. The minimum sample rate for the NI-9234 depends on the master timebase. Subsequently, I connected this channel to one of the channel. 有关可. cDAQ-9178 Product Certifications. The chassis provides the plug-and-play simplicity of USB to sensor and electrical measurements. To do so, select the Counter on the DIO module and use the DAQmx Channel to specify which terminal to output the signal on, as shown below. Controlador NI-DAQmx. cDAQ-9178 PXI-6133 cRIO Ring Terminal FPGA I/O Cable cDAQ-9172 The PWM wave is a periodic digital pulse. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。cdaq-9178、9179、9188、および9188xtには2つのpfiラインが搭載されているため、必要なトリガラインが2つ以下ならデジタルモジュールは必要ありません。 タスクでデジタルトリガを使用する方法の詳細については、 トリガを使用したデータ集録のテク. 5 g pk, ADC resolution of 24 bits, signal ranges of ± 5 V and sample rate of 51. 7 mm (0. 4 mm (1. You can find more release information on ni. Reference this information to ensure you install the correct version when upgrading or updating your system or software. コミュニティ. Whether you are creating a new configuration, replacing or expanding your current CompactDAQ System, or verifying that existing parts can be used in a different configuration. Hi, Does NI cDAQ-9178 have a builtin signal amplifier? Can I just connect a strain gauge bridge completion module without an amplifier to get the reading using the above DAQ model?JKMM. 16 in. 通过已安装的应用程序启动。. In a CompactDAQ system, a chassis is connected to your PC through USB or Ethernet, and then populated with one or more conditioned I/O modules for direct sensor connectivity. (a) Aluminum tape coated sample at heating test. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. In NI-DAQmx, you can configure virtual channels as part of a task or separate them from a task. 4. We would like to show you a description here but the site won’t allow us. Kevin_Price. The program below was created for a cDAQ-9178 which does not support adjusting the frequency while the DAQmx task is running. 이 섀시는 센서 및 전기 측정에 대한 USB의 단순한 플러그 앤 플레이 기능을 제공합니다. 如果您的设备或模块确实出现在Windows设备管理器中,请检查其显示的类别。. ) 63. those counters can interact with signals on. . Connect the NI cDAQ-9178 chassis to your host computer. The Gen II CompactDAQ chassis support a maximum of two synchronization pulse signals configured for your system. Hi! I want to control a Variable frequency driver through the cDAQ-9178. Fast Quote. 「電圧実効値」「電流実効値」「有効電力」「無効電力」「周波数」の5項目を得たいと考えており. All of what is posted on NI says the following code is needed when implementing bidirectional code, but nothing is stated as for input only counters. Required equipment: NI CompactDAQ chassis The Gen II CompactDAQ chassis support a maximum of two synchronization pulse signals configured for your system. Learn how to install, configure, and acquire data from your NI CompactDAQ USB. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements. 2. You can find more release information on ni. Ground the device using ring lug, grounding screw, and wire. This unit ships sealed in the manufacturer's static bag and includes the AEL15US12 power supply, and a 198506-02 Locking USB Cable. 0. The four needle valves were mounted on the reactor, one was used to supply the hydrogen gas and the other was attached to vacuum pump. Data were imported and processed in MathWorks MATLAB environment. Instruments data acquisition system, using a NI cDAQ-9178 chassis with a NI 9203 module to capture the values of the variables of inlet flow, outlet flow, inlet pressure and outlet pressure of the pipe and transmit them to a database accessible through a virtual instrument that was developed and described in [19]. デジタル周波数を収集するプロセスは極めて簡単です。. Free shipping. The chassis provides the plug‑and‑play simplicity of USB to sensor and electrical measurements with the higher performance data streaming of USB 3. 88 in. Access to the four counters of the CompactDAQ chassis is available any of the slots of the chassis; if. 4. 机箱通过即插即用的USB可轻松连接传感器和电气测量。. The cDAQ‑9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. NI cDAQTM-9171/9174/9178 User Manual NI CompactDAQ USB 2. 500 S/s, ±20 mA, 16-Channel C Series Current Input Module. Replace Connection Cable - If the cable is broken, change a new one and reconnect the device to PC. This example shows how to acquire IEPE data using an NI 9234. NI cDAQ-9178 Specifications These specifications are for the National Instruments CompactDAQ 9178 chassis only. You can use the NI‑9212 in a variety of applications that are not conducive for bank-isolated channels. The manual notes that a power input connector is required, which is a 2 positions 3. Use this article if you want to use a quadrature encoder or other sensor to measure frequency, period, pulse width, semi period, two edge. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. Expand the USB Settings tab and disable USB selective suspend settings. MiguelCSUN. Launch NI MAX software. The best replacement for this device will be a PXI, PXIe, or CompactDAQ chassis. During Debugging i tried connecting new cDAQ-9178 and tried connecting old PXIe but. Author. Please note that while the 2D dimensional drawings are available for most parts numbers, the 3D models are not. All experiments were carried out in a temperature-controlled room (20 ± 0. Order today, ships today. Re: CDAQ9178 & NI9775. 3. Ethernet、GPIB、シリアル、USBおよびその他のタイプの計測器をサポートします。. 75 in. Regards, Jens. On the right-hand panel, navigate to My System >> Devices and Interfaces and right-click a device. 11-11-2015 05:59 PM. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。 8‑Slot, USB CompactDAQ Chassis. The impact type vibration analyser has been utilized for the current testing purpose with the help of three components i. This document describes the range of software versions required for the aforementioned devices and links to the most recent. 2. The key parameter of the PWM wave is the duty cycle. The SCMS PC runs a LabVIEW readout program to receive and record sensor values. 7 mm (2. Author. NIは、NIソフトウェア製品のダウンロードをはじめ、NIおよび他社製計測器ドライバ、カメラネットワークファイルおよびデータプラグインのダウンロードを提供しています。. cDAQ-9178の内部経路について. I am using 2 of the counters to read frequency measurements. Our free 2-year warranty makes every Radwell purchase a dependable, reliable investment in your company's future. 49 in. If working through steps 1-12 does not result in finding and configuration your cDAQ try factory resetting the chassis. Solution. when connected to the USB 2 port, a beep is generated in Windows, along with a notification that the USB Device Not. 5. The sinusoidal forcing and the additive Gaussian noise are both generated by LabVIEW and transmitted to the Brüel and Kjaer electro-dynamic shaker, via an NI cDAQ-9178 with an NI 9263 module. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. 0 Chassis NI cDAQ-9171/9174/9178 User Manual July 2016 372838E-01 This page documents all the applicable standards and certifications for the cDAQ-9178 and provides downloadable certifications. NIの集録および信号調整デバイスをサポートします。. Table 1. 9 to 100. Notice that it’s important to connect to the computer with FlexLogger already installed. I find a cDAQ-9178 chassis in our lab without the power supply. g. 8‑Slot, USB CompactDAQ Chassis. Install the module in slot 8 of the NI cDAQ-9178 chassis. Dan_N. また、利用可能なすべてのエディションは、このダウンロードページから. The chassis provides the. The input power, q in, was controlled virtually via Labview 2013 and adjusted by voltage control through a TDK Lambda power supply (GEN 300-5). The solenoid valve was also powered directly by 110 V AC with an integrated switch for remote operation. Hi, Yes, you can import triggers and a sample clock into a cDAQ-9178 over the two PFI lines. 1, Fig. 5 mm pitch pluggable screw terminal with screw locks. b. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an external host. Attach the other end of the wire to the system safety ground. My chassis, device or module. 5 mm pitch. Attach the other end of the wire to the system safety ground. For the C Series I/O module specifications, refer to the documentation for the C Series I/O module you are using. Go to " Help » Find Examples. 7 and nidaqmx package for python. When I look in the Windows Device Manager, the device has a yellow exclamation point and says USB Flash Firmware Loader. Connect the ring lug to the ground terminal on the side of the NI cDAQ-9178 using the ground screw. You just need to specify that you will be using one PFI line for your triggering signal, and the other PFI line for your. Solution. PWM output on cDAQ-9178 Chassis PFI Line. The estimation particulars, including number of channels, channel setup, test rate, and pick up, are. The hammer acts as a source of disturbance in the study of the dynamic characteristics of the hybrid bearing. The chassis provides the plug-and-play simplicity of USB to sensor and electrical measurements. You can use this chassis with a. If you use the DAQmx Start Trigger VI it will be listed in the trigger source input pulldown. NI-DAQmx Readme Updates. Select Browse my computer for driver software. Hi, The front panel of cDAQ-9178 Chassis comes with two built in BNC connectors identified as PFI0 and PFI1. 0. NI-VISA. Using the default master timebase, the minimum sample rate is 1. Als Nächstes geht es darum, wie die CompactDAQ-Hardware verbunden wird. El chasis proporciona la simplicidad plug-and-play de USB a sensores y mediciones eléctricas. Use this page to find and install the latest firmware for your cDAQ-9181, cDAQ-9184, cDAQ-9185, cDAQ-9188, cDAQ-9188XT, cDAQ-9189 or cDAQ-9191. LabVIEW was selected because it interfaces well with the NI modules. Chassis CompactDAQ USB a 8 slot. NI-DAQmx 21. It also controls the timing, synchronization, and data transfer between C Series I/O. Other customers have asked for supporting the built-in PFI lines as well, and we. This behavior is caused by the Ethernet cDAQ chassis not being automatically reserved by the computer. ) 23. You can use this chassis with. 2. The cDAQ-9178 is a CompactDAQ USB chassis designed for small, portable sensor measurement systems. cDAQ-9178은 소형, 휴대용 센서 측정 시스템을 위해 설계된 CompactDAQ USB 섀시입니다. 2. This example uses an NI 9263 module in National Instruments® CompactDAQ Chassis NI cDAQ-9178. It also controls the timing, synchronization, and data transfer between C Series I/O modules and an. com I've found the 763000-01, however this looks like a standard power cord (same ones that power computers, monitors, etc). NI cDAQ TM-9171/9174/9178 User Manual NI CompactDAQ USB 2. ScansAvailableFcn = @ (src,evt). 8‑Slot, USB CompactDAQ Chassis. Options. ni cdaq-9178机箱和ni 9401数字量i / o模块. Install the NI 9229/9239 in slot 8 of the NI cDAQ-9178 chassis. Order toll free: 800. #LearnLabview#LearnElectronic#learnProgramming#futureTechnologyTwo NI cDAQ-9178 8-slot chassis, synchronized via NI 9469, with multiples of following modules; NI 9237 – Bridge Analog Input NI 9205 – 250 kS/s Analog Input NI 9207 – Voltage/Current Analog Input NI 9485 – SSR Relay NI 9234 – IEPE and AC/DC Analog Input Industry Transportation and Heavy Equipment Application Area200 kS/s, ±20 mA, 8-Channel C Series Current Input Module The NI‑9203 is intended for high-performance control and monitoring applications.